DSPA offers a wide range of multipurpose fixed extinguishing systems. A DSPA Fixed extinguishing system consists of one or more DSPA aerosol generators, which are activated by a detection & activation system (click here for more information). A DSPA aerosol generator is not pressurized and is installed inside the compartment or room that requires protection (for example: a server room, archive, generator room or to protect objects like electrical cabinets, switch boards or motor compartments). After activation, an aerosol cloud is generated, which expanse volumetrically, flooding the space and extinguishing the fire. The DSPA family of products consists of many different models which differ mainly in size and capacity. This way, we can always offer our customers the best solution for their unique situation. Below you will find the most basic information of our most populair aerosol generators:
| DSPA Type: 11-1 |
Basic specifications |
|

|
Weight |
0,55 kg |
| Active mass |
0,11 kg |
| Capacity Class A fire* |
1,1 m3 |
| Capacity Class B fire* |
3,4 m3 |
| Initiation current |
1,3 Amp |
| |
|
| Downloads: |
|
| Infosheet |
| Technical drawing |
| |
|
| DSPA Type: 11-2 |
Basic specifications |
|

|
Weight |
0,8 kg |
| Active mass |
0,17 kg |
| Capacity Class A fire* |
1,7 m3 |
| Capacity Class B fire* |
5,2 m3 |
| Initiation current |
1,3 Amp |
| |
|
| Downloads: |
|
| Infosheet |
| Technical drawing |
| |
|
| DSPA Type: 11-3 |
Basic specifications |
|

|
Weight |
1,3 kg |
| Active mass |
0,3 kg |
| Capacity Class A fire* |
3,1 m3 |
| Capacity Class B fire* |
9,2 m3 |
| Initiation current |
1,3 Amp |
| |
|
| Downloads: |
|
| Infosheet |
| Technical drawing |
| |
|
| DSPA Type: 11-4 |
Basic specifications |
|

|
Weight |
2,0 kg |
| Active mass |
0,9 kg |
| Capacity Class A fire* |
9,2 m3 |
| Capacity Class B fire* |
27,7 m3 |
| Initiation current |
1,3 Amp |
| |
|
| Downloads: |
|
| Infosheet |
| Technical drawing |
| |
|
| DSPA Type: 11-5 |
Basic specifications |
|

|
Weight |
4,5 kg |
| Active mass |
1,4 kg |
| Capacity Class A fire* |
14,4 m3 |
| Capacity Class B fire* |
43,1 m3 |
| Initiation current |
1,3 Amp |
| |
|
| Downloads: |
|
| Infosheet |
| Technical drawing |
| |
|
| DSPA Type: 11-6 |
Basic specifications |
|

|
Weight |
5,1 kg |
| Active mass |
2,4 kg |
| Capacity Class A fire* |
24,6 m3 |
| Capacity Class B fire* |
73,8 m3 |
| Initiation current |
1,3 Amp |
| |
|
| Downloads: |
|
| Infosheet |
| Technical drawing |
| |
|
| DSPA Type: 8-1 |
Basic specifications |
|

|
Weight |
10,0 kg |
| Active mass |
3,25 kg |
| Capacity Class A fire* |
33,3 m3 |
| Capacity Class B fire* |
100 m3 |
| Initiation current |
1,3 Amp |
| |
|
| Downloads: |
|
| Infosheet |
| Technical drawing |
| |
|
| DSPA Type: 8-2 |
Basic specifications |
|

|
Weight |
18,0 kg |
| Active mass |
6,7 kg |
| Capacity Class A fire* |
68,7 m3 |
| Capacity Class B fire* |
206,2 m3 |
| Initiation current |
1,3 Amp |
| |
|
| Downloads: |
|
| Infosheet |
|
| |
|
* Excluding safety factors |